What Information Should You Send for a UPS Quotation?

A practical checklist of UPS capacity, voltage, load, backup time and battery information to send before requesting a UPS quotation or selection support.

Why quotation information matters
A UPS quotation is more accurate when the supplier understands the real project conditions. If the request only says “I need a 20kVA UPS” or “please quote lithium battery”, important details may be missing.
For UPS projects, capacity, voltage, backup time and battery configuration all affect product selection, price and compatibility. Sending the right information at the beginning can reduce back-and-forth communication and help the project move faster.
Basic UPS information to send
  • Required UPS capacity in kVA or kW
  • Input phase and voltage
  • Output phase and voltage
  • Frequency requirement, such as 50Hz or 60Hz
  • Application: server room, IT room, network cabinet, small data center, industrial load or weak grid site
  • Quantity needed
  • Target market or installation country
Load and runtime information
UPS capacity should be checked against the real load, not only the equipment nameplate rating. If possible, send:
  • Real load in kW or kVA
  • Type of connected equipment
  • Required backup time
  • Whether the backup time is needed at full load or partial load
  • Whether the site uses a generator
Battery information for replacement projects
For UPS battery replacement, the battery side is often the most important part of the quotation. Send:
  • Existing UPS brand and model
  • UPS DC voltage or battery string voltage
  • Existing battery quantity and battery voltage
  • Existing battery capacity in Ah
  • Battery cabinet size or photos, if available
  • Whether you want lead-acid replacement, external battery cabinet or lithium retrofit
Information for lead-acid to lithium retrofit
Lithium retrofit needs compatibility review before quotation. Please send:
  • UPS model and DC voltage window
  • Charger voltage and charging current, if available
  • Current battery configuration
  • Required backup time and real load
  • Installation space and cable limits
  • Any communication or monitoring requirements
Information for OEM or local brand projects
If you are building your own UPS product line, also send:
  • Required logo or neutral branding
  • Packaging requirement
  • Datasheet or manual language
  • Target model range
  • Expected order quantity
  • Required certificates or import documents
Common quotation mistakes to avoid
  • Requesting battery price without UPS DC voltage
  • Asking for runtime without real load
  • Assuming lithium batteries can replace any lead-acid battery string directly
  • Comparing UPS prices without input/output voltage and backup time
  • Treating high-voltage UPS lithium battery systems as general BESS products
How ZYKEVO reviews your request
ZYKEVO can review the UPS capacity, voltage, battery configuration and backup time target before recommending ATLAS, TITAN, FORTRESS or a matching battery solution. For battery replacement and high-voltage lithium projects, compatibility must be checked before final quotation.
Send your UPS requirement
To request a quotation, send the UPS capacity, input/output voltage, real load, required backup time, battery preference and application site. If this is a replacement project, also send the existing UPS model and battery configuration.